Synthes rfna surgical technique

6 Surgical Technique fiffiCSLP Cervical Spine Locking Plate Surgical Technique 3. Insert Drill Guide Insert the Drill Guide 3.0 (387.201) into a middle plate hole (1). Choose the correct alignment to hold the plate, press the handle to attach the plate to the drill guide (2) and slide the catch forward to lock the drill guide in its position ...

– Soiled or used Synthes devices should not be loaded into a case for cleaning in a me-chanical washer. Soiled Synthes devices must be processed separate from trays and cas - es. Synthes cases are designed to be an organizational tool for the steam sterilization process, a storage tool for all medical devices and an organizational tool for ...Our LCP™ Distal Ulna Plate is part of the DePuy Synthes Locking Compression Plate (LCP) System that merges locking screw technology with conventional plating techniques. The plate features pointed hooks and locking screws in the head and is anatomically designed for use in distal ulna fractures. Product Specifications. How to Use This Product.8 DePuy Synthes Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4 Surgical Technique Use of funnel-shaped end of VA-LCP Drill Sleeve Use of freehand VA-LCP Drill Sleeve (03.111.004) Screw Insertion Techniques VA-LCP Drill Sleeve (03.110.000) VA-LCP Drill Sleeve, freehand (03.111.004), for off-axis drilling Funnel-shaped end for off-

Did you know?

Please read these instructions for use, the Synthes "Important Information" and the corresponding Surgical Technique Guide carefully before use. Ensure that you are familiar with the appropriate surgical technique. Wire Implants consist of various dimensions and types (stiff or bendable) of im-Distal: 9-12 mm, in 1-mm-Abstufungen (kurze Nägel) 9, 10, 12, 14 mm (lange Nägel) Kurze Nägel: 170 mm extrakurz 200 mm kurz 240 mm (ein Nagel passend für links und rechts) Lange Nägel: 300 mm-420 mm (linke und rechte Nägel, in 20-mm-Abstufungen) CCD-Winkel 125° und 130° Zusätzlich 135° für Nägel, Länge 240 mm.The Femoral Recon Nail System is an integrated nailing system designed to adapt to multiple surgical approaches. The FRN System provides the choice of Greater Trochanter (GT) and Piriformis Fossa (PF) entry points and anatomical nail designs to support surgical preferences and facilitate hospital standardization. Contact Us.simplified technique for . Locking Attachment Washer and for Condylar ... DePuy Synthes RFNA Nail/LAW Static Construct Design Verification . Report. 04/28/2020 ...

Synthes Rfna Technique Guide Jiang Zhi: Love Letters Jiang Zhi 2016-05-26 Jiang Zhi's flowers 'die' before our eyes -set aflame, they are on the brink of death, ... computerized surgical planning, personalized implant creation, and comprehensive radiographic analysis have given rise to new principles, techniques and possibilities, which are ...02.108.300, 02.108.300S, 02.108.301... View More. PRODUCT CODES. DESCRIPTION. The Pediatric LCP ™ Plate System is designed for stable fixation of varus, valgus or rotational osteotomies and trauma applications in pediatric orthopaedics. The plates feature a universal design to fit both the left and right femurs. Product Specifications.DESIGN EVIDENCE Results of the testing are summarized below, and comparison of 200 the nailing systems are displayed in Figure 6. 100 100 Pre-Fatigue Post-Fatigue Pre-Fatigue • The TFNA Nail mean slippage load in the pre-conditioning test Nail TFNA was 15% and 92% greater than the INTERTAN Nail and Gamma3 Nail, respectively; the TFNA Nail mean slippage load in the post-conditioning test was ...The VIPER® 2 MIS System is a single platform, minimally invasive spine surgery solution that enables treatment of degenerative and complex MIS cases.

Ultimately, the SYMPHONY™ System helps streamline procedures and create efficiencies for the surgeon and operating room staff who are treating patients with complex cervical spine disorders. "The SYMPHONY™ System builds on a deep foundation of DePuy Synthes' expertise in treating diseases that affect the cervical spine," said Nadav ...TM System Surgical Technique DePuy Synthes 5 Step 1 OR Set-Up Precautions: It is recommended to use a Jackson Table to assist in achieving the proper patient positioning and an unrestricted fluoroscopic view. Confirm the C-Arm will allow for easy rotation in the lateral, oblique, and A/P positions around the table.CORAIL™ Total Hip System • Surgical Technique 13 CAUTION: This section is for Size 6 Stems only. This stem is contraindicated with hemiarthroplasty surgery. This stem must not be implanted in patient weighing more than 60kg (130lb). All 12/14 heads available in the DePuy Synthes Portfolio are compatible with this stem. Surgical Technique ….

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Synthes rfna surgical technique. Possible cause: Not clear synthes rfna surgical technique.

System. PHILOS ® System is an anatomical LCP plating system for proximal humerus fracture fixation. It includes the PHILOS ® Percutaneous Aiming System, for a less invasive transdeltoid approach. Unfortunately, we can't detect an electronic copy of the Instructions for Use (IFU) you are seeking. You can locate the IFU for this product by:RIA 2 (Reamer Irrigator Aspirator) Surgical Technique DePuy Synthes 3. PREPARATION. 1. SELECTION OF THE APPROPRIATE RIA 2 KIT. 03.404.000S. RIA 2 Bone Harvesting Kit, 520 mm, sterile. 03.404.001S. RIA 2 Reaming Kit, 520 mm, sterile Select the appropriate RIA 2 kit based on procedure type.

The TFNA (Trochanteric Fixation Nail Advanced) Proximal Femoral Nailing System (DePuy Synthes) is frequently used for intramedullary fixation of proximal femoral fractures. The aim of this study was to evaluate all TFNA implant fractures at a UK trauma unit to ascertain any patient or surgical factors associated with implant failure.2 OPERACE Surgical Technique INNOVATION AND SWISS QUALITY The OPERACE instrument set is used to remove implant screws made of titanium, titanium alloys and stainless steel - particu-larly damaged screws. OPERACE is the result of the combined innovative power of PB Swiss Tools, the Swiss manufacturer of high-quality tools, and2 Surgical Technique • Variable Angle Locking Hand System The DePuy Synthes Variable Angle Locking Hand System consists of plates that are anatomic, procedure-specific, and available in both stainless steel and titanium. The Variable Angle Locking Hand System offers instrumentation to aid in:

murdaugh holly street hampton sc Please read these instructions for use, the Synthes brochure "Important Information" and the corresponding surgical technique Compact Midface (DSEM/CMF/0316/0121) carefully before use. The Compact Midface, Orbital plates, and Orthogmathic Systems offer a wide range of different sizes, lengths, and thickness of plates and screws implants. All6 Surgical Technique • Large and Medium External Fixators The AO Principles of Fracture Management 1 Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3 rd ed. Berlin, Heidelberg New York: Springer 1991. 2 Buckley RE, Moran CG, Apivatthakakul T. AO Principles of Fracture Management: 3 rd ed. Vol. 1: Principles, Vol. 2: Specific fractures. jonathan lemire hair piecehigh horse cannabis company chaparral reviews Background. The standard approach to lateral tibial plateau fractures involves elevation of the iliotibial band (IT) and anterior tibialis origin in continuity from Gerdy's tubercle and metaphyseal flare. We describe an alternative approach to increase lateral plateau joint exposure and maintain iliotibial band insertion to Gerdy's tubercle.The FRN-ADVANCED System is intended for treatment of fractures in adults and adolescents in which the growth plates have fused. Intended applications include: Subtrochanteric fractures. Ipsilateral neck/shaft fractures. Femoral shaft fractures. Impending pathologic fractures. Malunions and nonunions. Get in Touch with a Sales Consultant. alpine school district skyward The Proximal Femoral Nail Antirotation, known as the PFNA, is an intramedullary implant for the treatment of unstable trochanteric femoral fractures. This pr...8 Surgical Technique • TFN-ADVANCED™ Proximal Femoral Nailing System (TFNA) Preparation 1. Position patient Position the patient in the lateral decubitus or supine position on a fracture or radiolucent table. Position the image intensifi er to enable visualization of the proximal femur in both the AP and lateral planes. western sizzlin opelika menurastros en miami opa lockagatlinburg weather 10 day LCP™ Proximal Femur Hook Plate. 242.12, 242.120S, 242.121... The LCP™ Proximal Femur Hook Plate is designed to address complex fractures of the proximal femur and is part of the LCP Periarticular Plating System. It features Combi holes in the plate shaft to combine a dynamic compression unit (DCU) hole with a threaded locking hole.Learn the Femoral neck fracture: Proximal femoral nail (Synthes long TFNA) for Intertrochanteric fracture surgical technique with step by step instructions on OrthOracle. Our e-learning platform contains high resolution images and a certified CME of the Femoral neck fracture: Proximal femoral nail (Synthes long TFNA) for Intertrochanteric ... cane corso puppies for sale in louisiana 2.7 mm/3.5 mm LCP® Distal Fibula Plates Surgical Technique DePuy Synthes 9 5 Insert plate Expose the fibula proximally as needed for plate application. In the majority of circumstances, an open approach for plate application will be performed. Occasionally, a submuscular plate insertion will be performed using a minimally invasive technique.Position the image intensifier as for an AP view of the proximal femur. Using long forceps, hold the ruler paral-lel to the femur on the lateral side of the upper leg. Position the ruler such that the end is located at or just below the level of the tip of the greater trochanter. Mark the skin on the lateral side. american airlines federal credit union routing numberprofrac pleasanton txi love you text art At the end of this video, you should be able to describe the steps for placing the RFN-Advanced Retrograde Femoral Nailing System. This content is intended for Health Care Professionals in the United States.